Room thermostat height uk.
Whilst most wet ufh systems usually involve builders and plumbers bc do recognise the manufacturers recommendations and reasons for a thermostat height of 1500mm for optimum performance building regulation guidance documents are not set in stone and very much like your wiring regs often the manufacturers recommendations are considered seriously yes we do have a conflict with part m and.
We are the leading suppliers of domestic heating and combustion controls in the uk with products that include time temperature gas and water controls.
Drayton 22083sx room thermostat 75750 product rating 3 7 out of 5 stars compare.
Building regulations are driven by energy efficiency and having a greater impact on more work undertaken within the home.
I see lots still being mounted at 1500mm.
I am wondering what the requirement for the mounting height of a central heating thermostat in a dwelling must be.
The location you choose for the thermostat can affect whether you will feel warm or cold in your new room.
Their is no current regulation which states thermostat have to be in entrance hall although this is a reasonable good practice as your thermostat needs to read the coolest area to allow your main area to be comfortable.
The central heating system is a controlled service and subject to building regulations produced by the government.
Never have had this as issue before and as far as i can recall manufacturers recommend around 1 5m.
450 1200 mm from floor level.
What height do you folks mount room stats at.
If you are remodeling a room you will have to decide where to place the room thermostat.
In the old days before ada rules the general rule of thumb was 60 to be ada compliant you place them at 42 but many contractors choose to place them at the same level of the wall switches.
7 day or 5 2 day programmable.
These readings are key when programming setback temperatures and assist in running an efficient heating system so if a thermostat is installed in a very cold or overly warm room it may not accurately reflect the true temperature of.
2 4 or 6 on off periods per day.
Thermostats measure the temperature of the room that they are placed in via an air sensor and or a floor sensor.
On mar 09 2010.
Is it covered by part m of the building regulations as are sockets and light switches i e.
The hitler from building control ni has flagged one i have installed 1 5m as being too high and wants it dropped to 1 2m to top of it 001 9898.
Click collect deliver update.
Our product range is designed to provide the homeowner with the best in comfort energy and health solutions.
Determining the best room thermostat height and location written by doityourself staff.